| Impulse Voltage Testing |
||||||||
Generators |
||||||||
|
CDY series |
|
|||||||
|
|
||||||||
| [Impulse Voltage Generator] | ||||||||
![]() |
CDY series impulse test systems can be used to generate impulse voltages simulating lightning strokes and switching surges. The stage energy is 2.5 kJ~1620kJ. Max. Charging voltage is 100~7200kV. Applications covered include testing according to IEC, ANSI/IEEE as well as other national standards. The basic system can be upgraded in various ways for special tests and for greater ease of operation. A number of additional circuits and components allow optimizing the impulse test system for tests on different kinds of high voltage test objects. The generator is due to its unique, modular, patented structure perfectly suited for transportation and easy on-site erection. Also the internal inductance is the lowest ever built. |
|||||||
|
|
||||||||
Control & Measuring System |
||||||||
IMCS |
||||||||
| [Computer Control & Measuring System] | ||||||||
|
|
||||||||
![]() |
IMCS Impulse voltage control system is specifically designed for the needs of HV impulse testing. It is an automatic information platform unit composed by measurement, control high voltage equipment, the whole system full automatic data analyzing process through the industrial controlled computer system. The use of the industrial controlled computer system as information platform permits the impulse voltage generator wide update and expanding opportunity, meanwhile gives to the construction of test laboratory information center a basic hardware. The above parts are designed and manufactured according to the industry and technology standards, the system is reliable and stable, and insure the accuracy and the operating speed. A Report File can be created for further data processing. |
|||||||
| TR-AS | ||||||||
| [Digital Impulse Voltage Measuring System] | ||||||||
![]() |
According to IEC 61083-1/2 for measurement and analysis of the impulse waveform of lightning and switching impulse voltages during H.V. tests (peak value, front-time, time-to-half-value, time-tochopping), menu-oriented control- and graficprogram, indoor use. With 10, 12 or 14 Bit resolution suitable for comparison of records during transformer tests With DKD-Calibration suitable as Reference Standard and Reference Measuring System for full and chopped waves. All variants upgradeable to 4 channels with 200 MS/s and 14 Bit. Control output for calibrator |
|||||||
PS: we can also provide the measuring system of Dr. Strauss, if customer needs. All the details: Such as technical data and price, please contact us! |
||||||||
| HIAS1214 | ||||||||
| [Computer Control & Measuring System] | ||||||||
![]() |
HIAS1214 Computer Control & Measuring System is specifically designed for the needs of HV impulse testing. It is used WHVD-100 digital high voltage transient recorder of the third generation, its system reliability, set level, speed and functionality on the prototype has significant increased. With high-speed, large capacity transient signal acquisition module HS-120, program-controlled amplifiers and control circuit as the core components. Over various parts of industrial technology standards in accordance with the design and manufacture, they constitute a mutual organically excellent all-digital precision measurement, high-speed (120 MS / s), large capacity (maximum of 512 M) test record of the impulse high voltage system. A Report File can be created for further data processing. |
|||||||
| SG3003 | ||||||||
| [Digital Impulse Voltage/ Current Peak Value Meter] | ||||||||
![]() |
SG3003 high-precision digital pulse peak value meter is mainly used in high-voltage pulse and the pulse current peak signal measurement. Signal measurement from 1V-1200V using advanced automatic convert technology and pulse signal plus or minus automatic identification technology, measurement of the peak can reach 0.5% linearity. |
|||||||
| OP-T | ||||||||
| [ Digital Light-controlled Ignition Device ] | ||||||||
![]() |
OP-T digital light-controlled ignition device applies to the ignition control of simultaneous trigger in HV tests. Synchronous ignition device is composed of "digital synchronous ignition box optical controller" and "digital light-controlled synchronous ignition boxes." Light-controller receives the narrow pulse width ignition signal and converts it into a light trigger signal, and then sends the signal to ignition box through digital fiber-optic transmission without delay. It instantaneous triggers ignition boxes and makes synchronous high-voltage ignition pulse, to throughout HV ignition sphere gap. |
|||||||
Chopping Gaps |
||||||||
SGFS |
||||||||
[ Automated Multiple Chopping Gap ] |
||||||||
![]() |
The multiple chopping gap is used to chop lightning impulses on the front and/or on the tail. The multiple chopping gap serves simultaneously as a load capacitor for the impulse generator and allows excellent reproducibility of the chopping time and does not distort the wave shape until the chopping point. The sphere distance is automatically adjusted and operated by the controls of SG2010 and SG2011. A manual control box is available as well. |
|||||||
SGS H & SGS V |
||||||||
[ Horizontal & Vertical Sphere Gap ] |
||||||||
![]() |
The sphere gap type SGS H or SGS V can be used for Impulse, AC and DC voltage calibration according to the IEC 60052 recommendation. The spheres are arranged vertically or horizontally, one being mobile. In the vertical version the mobile sphere is remotely adjusted by using an electrical drive. In the horizontal version, both spheres are mounted on columns of insulating materials, hence enabling to superimpose impulse AC and DC voltages. It is also possible to use the gap in a peaking circuit. For the chopping of lightning impulses the sphere gap can be equipped with the optional chopping device.
|
|||||||
| RE-2302 | ||||||||
| [Recurrent Surge Generator] | ||||||||
RE-2302 model recurrent pulse generator is a sort of equipment simulating various pulse waveforms, through the selecting switch change the pulse line different parameters, you can get the same high voltage pulse generation wave form of the high voltage test. It can be used for motors, reactors, power transformers, instrument transformer coil internal pulse, and impulse voltage distribution (potential gradient) simulation test and insulation deficiency location. There is no damage to the coil. It can also be used for high voltage impulse generator’s middle and terminal wave parameters preset, test system transmission properties and cable and coil transient waveform measurement. The charging voltage amplitude is from 0~400V tunable. Repeated frequency is 25 Hz. |
||||||||
![]() |
||||||||
| Please fill your request in questionnaire >Impulse Voltage Testing and kindly send it to > gukaigukaigukai@163.com | ||||||||
|
|
||||||||
| Copyright © Samgor Technology www.samgor.com |
![]() ![]() ![]() ![]() ![]() |
Home | About Us | News | Products | Services | Downloads | Contact Us | ||||||
|
|
||||||||
|
|
||||||||
|
|
|
|
|
|||||